English

ZDS-FG2122

ZDS-FG2122 Ultra-High-Temperature Inorganic Adhesive

ZDS-FG2122 bonds refractory, ceramic and glass-lined equipment for demanding thermal service. It offers chemical-media resistance and flame-resistant performance.

Product overview

Ultra-high-temperature inorganic bonding

ZDS-FG2122 is an inorganic adhesive for bonding furnace and refractory components, ceramic and glass-lined equipment, industrial pipelines and protective linings. It is intended for applications that require bonding in high-temperature equipment.

Its resistance to chemical media, high-temperature service capability and flame-resistant performance help with demanding equipment environments. Selection should account for the contact surfaces, available access, operating temperature and the fluid exposure at the bonding area.

Key material properties

  • Chemical resistance: Identify the fluid, concentration and temperature when discussing suitability.
  • Temperature capability: Compare the service-temperature limits in the table with the operating conditions.
  • Flame resistance: A material property to consider for the intended equipment application.

Evaluate the material

ZDS-FG2122 technical specifications

PropertyValue / conditions
Product modelZDS-FG2122
Product seriesZDS-FluidGlide
Product familyHigh-temperature & chemical service
Substrates and equipmentFurnace and refractory components, ceramic and glass-lined equipment, industrial pipelines, protective linings
Form and colorAdhesive; Typical: Dark grey
Working time at 25°CTypical: 30-45 min
Initial cure at 25°CTypical: 4-6 h
Full cure / cure conditionsHeat cure required
Service temperature-60 to 1800°C
Recommended application temperatureRecommended: 15°C to 35°C
Recommended application thicknessRecommended: 3-8 mm

Questions about your operating conditions?

Bonding for high-temperature equipment

Furnace and refractory component bonding

ZDS-FG2122 bonds furnace and refractory components where the joint will face high heat. Its high-temperature service capability and flame-resistant performance suit equipment that operates in demanding thermal conditions. Confirm that the component materials and service conditions match the planned application.

Ceramic, glass-lined and lining applications

Use ZDS-FG2122 for bonding ceramic and glass-lined equipment, industrial pipelines or protective linings. Resistance to chemical media is useful when the operating fluid and exposure conditions are known. Review the contact area, access and the operating temperature before selecting the product.

Dark grey adhesive being applied to a prepared refractory component beside an industrial furnace assembly.
Technician applying dark grey adhesive to a prepared ceramic-lined equipment component in an industrial workshop.

Prepare the work surface

Prepare the bonding area using the product-specific preparation instructions.

  1. Identify the contact surfaces and inspect for loose material and contamination.
  2. Arrange access to the full work area and the tools needed for the next step.
  3. Address contamination using the preparation method specified for this product and the actual surface.
Prepared ceramic and refractory bonding surfaces inspected for loose material and contamination on an industrial workbench.

Plan the work

Application and cure planning

  1. Prepare the bonding area and arrange access and tools before starting.
  2. Mix the components according to the product instructions after surface preparation and setup are complete.
  3. Apply the adhesive to the prepared contact area according to the product instructions.
  4. Use the technical table to plan the cure stages. Follow the applicable repair or application procedure for handling, loading and return to service.

Product selection questions

How much working time is available?

The typical working time at 25°C is 30-45 min. Complete surface preparation and setup before mixing.

What is the full-cure schedule?

Full cure: Heat cure required. Follow the product instructions for the applicable cure conditions.

What temperatures apply?

Recommended application temperature: 15°C to 35°C. Service temperature: -60 to 1800°C. Application and service temperatures describe different conditions.

What thickness is recommended?

Recommended: 3-8 mm. Use the stated thickness type and range when planning the work.

Scroll to Top
ZDSCHEM
TECHNICAL & COMMERCIAL SUPPORT

Tell us what you need to repair.

Share the equipment, substrate, damage and operating conditions. Our team will review the right product family and next step.

  • 01Application reviewProduct direction based on real service conditions
  • 02Samples & validationSupport before bulk procurement
  • 03Global B2B supplyDocumentation, packaging and export coordination

What helps us respond faster
Photos · temperature · pressure · chemical medium · required quantity

Get Technical Support

By submitting an enquiry, you agree that ZDSChem may use the information to assess and respond to your request. View our Privacy Policy.